The EcoFlow RIVER 2 is a compact and lightweight portable power station that can power up to 10 devices simultaneously. It has a battery capacity of 256Wh, an AC output of 300W continuous and 600W surge, and multiple charging options, including solar, car, and grid. It also has a smart display screen and an app that let you monitor and control the device remotely.
However, like any electronic device, the EcoFlow RIVER 2 may encounter some errors or issues during operation. These errors are indicated by icons that appear on the display screen or the app. Some of these errors are minor and can be resolved by following some simple steps. Others may require more attention or professional assistance.
In this post, we will explain what each error icon means and how to fix it. We will also provide some tips on how to prevent or avoid these errors in the future.
Battery Discharge Low Temperature Protection
This error icon means that the EcoFlow RIVER 2 has detected a low temperature in the battery. This could be caused by:
- Using the device in a cold environment below 10°F (-12°C).
- Storing the device in a cold place for a long time without recharging it.
To fix this error, you should:
- Move the device to a warmer place above 10°F (-12°C).
- Recharge the device as soon as possible using an approved charger and cable.
- Wait for the device to warm up before resuming operation.
Battery Discharge High Temperature Protection
This error icon means that the EcoFlow RIVER 2 has detected a high temperature in the battery. This could be caused by:
- Overloading the device with too many appliances or devices that exceed its power capacity.
- Placing the device in direct sunlight or near a heat source.
- Blocking the ventilation holes or fans of the device.
To fix this error, you should:
- Reduce the load on the device by unplugging some appliances or devices.
- Move the device to a cooler and shaded place away from heat sources.
- Check and clear any obstructions on the ventilation holes or fans of the device.
- Wait for the device to cool down before resuming operation.
Battery Charge Low Temperature Protection
This error icon means that the EcoFlow RIVER 2 has detected a low temperature in the battery while charging. This could be caused by:
- Charging the device in a cold environment below 41°F (5°C).
- Storing the device in a cold place for a long time without recharging it.
To fix this error, you should:
- Move the device to a warmer place above 41°F (5°C).
- Recharge the device as soon as possible using an approved charger and cable.
- Wait for the device to warm up before resuming operation.
Battery Charge High Temperature Protection
This error icon means that the EcoFlow RIVER 2 has detected a high temperature in the battery while charging. This could be caused by:
- Charging the device with an incompatible charger or cable.
- Placing the device in direct sunlight or near a heat source.
- Blocking the ventilation holes or fans of the device.
To fix this error, you should:
- Use only an approved charger and cable to charge the device.
- Move the device to a cooler and shaded place away from heat sources.
- Check and clear any obstructions on the ventilation holes or fans of the device.
- Wait for the device to cool down before resuming operation.
AC Output Overload Protection
This error icon means that the EcoFlow RIVER 2 has detected an overload on the AC output. This could be caused by:
- Connecting appliances or devices that exceed the rated power of the device (300W continuous, 600W surge).
- Connecting appliances or devices that have a high starting power or inrush current, such as motors, compressors, pumps, etc.
- Connecting multiple appliances or devices at the same time that add up to more than the rated power of the device.
To fix this error, you should:
- Disconnect the overloaded appliance or device and restart the device.
- Connect only appliances or devices that are within the power limit of the device.
- Connect only one appliance or device at a time that has a high starting power or inrush current.
Fan Blockage
This error icon means that there is something blocking the fan of the EcoFlow RIVER 2. This could be caused by:
- Dust, dirt, debris, or foreign objects entering or accumulating on the fan.
- Placing something on top of or near the fan.
To fix this error, you should:
- Turn off and unplug the device from any power source.
- Check and clear any obstructions on or around the fan.
- Restart the device and check if the error icon disappears.
Conclusion
We hope this post has helped you understand and fix the common error icons on your EcoFlow RIVER 2 portable power station. If you have any questions or issues, please contact EcoFlow customer service for further assistance. Remember to always use your device safely and responsibly, and enjoy the portable power life!